Control |
Control Method |
Keypad / Terminal / Communication option selectable |
Frequency Setting Resolution |
Analog: -10~10[V], 0~10[V], 4~20[mA] / Digital: Keypad, Pulse train input |
Frequency Accuracy |
1% of the maximum output frequency |
Operation Function |
PID control, 3-wire operation, Frequency limit, Second function, Anti-forward and reverse direction rotation,
Commercial transition, Speed search, Power braking, Leakage reduction, Up-down operation, DC braking,
Frequency jump, Slip compensation, Automatic restart, Automatic tuning, Energy buffering, Flux braking,
Fire Mode |
Input |
Multi-Function Terminal
Standard I/O (5 Points)
Multiple I/O (7 Points) |
NPN (Sink) / PNP (Source) Selectable |
Function: Forward run, Reverse run, Reset, External trip, Emergency stop, Jog operation, Multi-step
frequency-high, middle, low, Multi-step acceleration/ deceleration-high, middle, low, DC braking at
stop, 2nd motor select, Frequency up/down, 3-wire operation, Change into normal operation during PID
operation, Change into main body operation during option operation, Analog command frequency fixing,
Acceleration/deceleration stop etc. Selectable |
Analog Input |
V1: -10~10V, selectable V2: 0~10V/I2 4~20mA |
Pulse Train |
0~32kHz, Low level: 0~2.5V, High level: 3.5~12V |
Output |
Open Collector Terminal |
Fault output and drive operation status output |
less than DC 24V 50mA |
Multi-function Relay |
(N.O., N.C.) less than AC 250V 1A, less than DC 30V 1A |
Analog Output |
Selectable 0~12Vdc/0~24mA Frequency, Output current, Output voltage, DC stage voltage etc. selectable |
Pulse Train |
Maximum 32kHz, 10~12 [V] |
Protective Function |
Trip |
Over current trip, External signal trip, ARM short circuit current trip, Over heat trip, Input imaging trip,
Ground trip, Motor over heat trip, I/O board link trip, No motor trip, Parameter writing trip, Emergency stop
trip, Command loss trip, External memory error, CPU watchdog trip, Motor normal load trip, Over voltage
trip, Temperature sensor trip, Drive over heat, Option trip, Output imaging trip, Drive overload trip, Fan trip,
Pre-PID operation failure, External break trip, Low voltage trip during operation, Low voltage trip, Safety
A(B) trip, Analog input error, Motor overload trip, |
Alarm |
Command loss trip alarm, overload alarm, normal load alarm, drive overload alarm, fan operation alarm,
resistance braking rate alarm, number of corrections on rotor tuning error |
Momentary Power Loss |
HD below 15ms (ND below 8ms): Continuous operation (To be within rated input voltage, rated output)
HD above 15ms (ND above 8ms): Automatic restart operation enable |
Environment |
Cooling Type |
Forced fan cooling structure
Forced cooling type: 0.4~15 kW 200V/0.4~75 kW 400V (excluding some models) |
Protection Degree |
IP20/UL Open (Default), UL Enclosed type 1 (Option), IP66/NEMA 4X (Option) |
Ambient Temperature |
Ambient temperature under the condition of no ice or frost. HD: -10~50˚C(14~122˚F) / ND: -10~40˚C(14~104˚F)
[However, recommended to use load below 80% when using at 50°C under light load] |
Humidity |
Relative humidity below 95% RH (no dew formation) |
Storage Temperature |
-20~65℃(-4~149°F) |
Location |
No corrosive gas, flammable gas, oil mist and dust etc. indoors (Pollution degree 3 environment) |
Altitude, Vibration |
Below 1,000m (From 1000 to 4000m, the rated input voltage and rated output current of the drive must be
derated by 1% for every 100m.), below 9.8m/sec2 (1G) |
Pressure |
70~106kPa |
Certificate/Compliance |
UL, CE |
|