LSLV S100 High-Performance Standard Drive

Key Features

     
  • Powerful Performance
    • Sensorless control functions
    • Starting torque (200%/0.5Hz)
  • Space Efficient Design
    • Side-by-side installation
    • Decreased dimensions
  • Suitable for Users
    • Various field networks
  • Standard Compliance
    • Built-in EMC filter
    • International standards
  • Safety Functions
    • Built-insafe torque off (STO)
    • Redundant input circuit
① Rated Motor
0004 0.4kW
0008 0.75kW
0015 1.5kW
0022 2.2kW
0037 3.7 kW
0040 4.0kW
0055 5.5kW
0075 7.5kW
0110 11kW
0150 15kW
0185 18.5kW
0220 22kW
0300 30kW
0370 37kW
0450 45kW
0550 55kW
0750 75kW
② Input Voltage
1 1-phase 200~240[V]
2 3-phase 200~240[V]
4 3-phase 380~480[V]
③ Keypad
E LED Keypad
C LCD Keypad
④ UL Type
O UL Open
X IP66/NEMA 4X
EMC Filter
F Built-in EMC(C2)
N Non-EMC
⑥ Reactor
D Built-in DC Reactor
N Non Reactor
   
3-Phase 200V Class (0.4~7.5kW)
0004 0008 0015 0022
Motor Rating Heavy Duty HP 0.5 1.0 2.0 3.0
kW 0.4 0.75 1.5 2.2
Normal Duty (ND) HP 1.0 2.0 3.0 5.0
KW 0.75 1.5 2.2 3.7
Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2
Normal Duty (ND) 1.2 2.3 3.8 4.6
Rated Current (3-Phase Input) [A] Heavy Duty (HD) 2.5 5.0 8.0 11.0
Normal Duty (ND) 3.1 6.0 9.6 12.0
Frequency [Hz] 0~400Hz (IM Sensorless: 0~120[Hz])
Voltage [V] 3-phase 200~240V
Input Rating Voltage [V] 1-phase 200~240VAC (-15% ~ +10%)
Frequency [Hz] 50~60Hz(±5%)
Rated Current [A] Heavy Duty (HD) 4.4 9.3 15.6 21.7
Normal Duty (ND) 5.8 11.7 19.7 24.0
Weight [kg] 0.9 (1.14) 1.3 (1.76) 1.5 (1.76) 2.0 (2.22)
3-Phase 400V Class (0.4~7.5kW)
0004 0008 0015 0022 0037 0040 0055 0075 0110 0150
Motor Rating Heavy Duty HP 0.5 1.0 2.0 3.0 5.0 5.4 7.5 10.0 15.0 20.0
kW 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11.0 15.0
Normal Duty (ND) HP 1.0 2.0 3.0 5.0 5.4 7.5 10.0 15.0 20.0 25.0
KW 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11.0 15.0 18.5
Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2 6.1 6.5 9.1 12.2 17.5 22.9
Normal Duty (ND) 1.2 2.3 3.8 4.6 6.9 6.9 11.4 15.2 21.3 26.3
Rated Current (3-Phase Input) [A] Heavy Duty (HD) 2.5 5.0 8.0 11.0 16.0 17.0 24.0 32.0 46.0 60.0
Normal Duty (ND) 3.1 6.0 9.6 12.0 18.0 18.0 30.0 40.0 56.0 69.0
Rated Current (1-Phase Input) [A] Heavy Duty (HD) 1.5 2.8 4.6 6.1 8.8 9.3 13.0 18.0 26.0 33.0
Normal Duty (ND) 1.8 3.3 5.7 6.6 9.9 9.9 16.0 22.0 31.0 38.0
Frequency [Hz] 0~400Hz (IM Sensorless: 0~120[Hz])
Voltage [V] 3-phase 200~240V
Input Rating Voltage [V] 3-phase 200~240VAC (-15% ~ +10%) / Single-Phase 240VAC (-5%~+10%)
Frequency [Hz] 50~60Hz(±5%) (In case of single phase input, input frequency is only 60Hz (±5%))
Rated Current [A] Heavy Duty (HD) 2.2 4.9 8.4 11.8 17.5 18.5 25.8 34.9 50.8 66.7
Normal Duty (ND) 3.0 6.3 10.8 13.1 19.4 19.4 32.7 44.2 62.3 77.2
Weight [kg] 0.9 0.9 1.3 1.5 2.0 2.0 3.3(3.1) 3.3(3.1) 4.6(4.4) 7.1(6.9)
3-Phase 400V (0.4~75kW)
0004 0008 0015 0022 0037 0040 0055 0075 0110 0150 0185 0220 0300 0370 0450 0550 0750
Motor Rating Heavy Duty HP 0.5 1.0 2.0 3.0 5.0 5.4 7.5 10.0 15.0 20.0 25.0 30.0 40.0 50.0 60.0 75.0 100
kW 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0
Normal Duty (ND) HP 1.0 2.0 3.0 5.0 5.4 7.5 10.0 15.0 20.0 25.0 30.0 40.0 50.0 60.0 75.0 100.0 120
KW 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 50.0 60.0 75.0 100.0 120
Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2 6.1 6.9 9.1 12.2 18.3 22.9 29.7 34.3 46 57 69 84 116
Normal Duty (ND) 1.5 2.4 3.9 5.3 7.6 7.6 12.2 17.5 22.9 29.0 33.5 44.2 55 67 75 106 126
Rated Current (3-Phase Input) [A] Heavy Duty (HD) 1.3 2.5 4.0 5.5 8.0 9.0 12.0 16.0 24.0 30.0 39.0 45.0 61.0 75.0 91 110 152
Normal Duty (ND) 2.0 3.1 5.1 6.9 10.0 10.0 16.0 23.0 30.0 38.0 44.0 58.0 75.0 91.0 107.0 142 169
Rated Current (1-Phase Input) [A] Heavy Duty (HD) 0.8 1.5 2.3 3.1 4.8 5.4 7.1 9.5 15.0 18.0 23.0 27.0 32 39 47 57 78
Normal Duty (ND) 1.3 1.9 3.0 3.9 5.9 5.9 9.5 14.0 18.0 23.0 27.0 35.0 39 47 55 73 87
Frequency [Hz] 0~400Hz (IM Sensorless: 0~120[Hz])
Voltage [V] 3-phase 200~240V
Input Rating Voltage [V] 3-phase 200~240VAC (-15% ~ +10%) / Single-Phase 240VAC (-5%~+10%)
Frequency [Hz] 50~60Hz(±5%) (In case of single phase input, input frequency is only 60Hz (±5%))
Rated Current [A] Heavy Duty (HD) 1.1 2.4 4.2 5.9 8.7 9.8 12.9 17.5 26.5 33.4 43.6 50.7 56 69 85 103 143
Normal Duty (ND) 2.0 3.3 5.5 7.5 10.8 10.8 17.5 25.4 33.4 42.5 49.5 65.7 69 85 100 134 160
Weight [kg] 0.9 (1.18) 0.9 (1.18) 1.3 (1.77) 1.5 (1.80) 2.0 (2.23) 2.0 (2.23) 3.3 (3.1) 3.4 (3.2) 4.6 (4.4) 4.8 (4.6) 7.5 (7.3) 7.5 (7.3) 25.8 34.4 34.4 41.8 43.8
Control
Control Method Keypad / Terminal / Communication option selectable
Frequency Setting Resolution Analog: -10~10[V], 0~10[V], 4~20[mA] / Digital: Keypad, Pulse train input
Frequency Accuracy 1% of the maximum output frequency
Operation Function PID control, 3-wire operation, Frequency limit, Second function, Anti-forward and reverse direction rotation, Commercial transition, Speed search, Power braking, Leakage reduction, Up-down operation, DC braking, Frequency jump, Slip compensation, Automatic restart, Automatic tuning, Energy buffering, Flux braking, Fire Mode
Input Multi-Function Terminal Standard I/O (5 Points) Multiple I/O (7 Points) NPN (Sink) / PNP (Source) Selectable
Function: Forward run, Reverse run, Reset, External trip, Emergency stop, Jog operation, Multi-step frequency-high, middle, low, Multi-step acceleration/ deceleration-high, middle, low, DC braking at stop, 2nd motor select, Frequency up/down, 3-wire operation, Change into normal operation during PID operation, Change into main body operation during option operation, Analog command frequency fixing, Acceleration/deceleration stop etc. Selectable
Analog Input V1: -10~10V, selectable V2: 0~10V/I2 4~20mA
Pulse Train 0~32kHz, Low level: 0~2.5V, High level: 3.5~12V
Output Open Collector Terminal Fault output and drive operation status output less than DC 24V 50mA
Multi-function Relay (N.O., N.C.) less than AC 250V 1A, less than DC 30V 1A
Analog Output Selectable 0~12Vdc/0~24mA Frequency, Output current, Output voltage, DC stage voltage etc. selectable
Pulse Train Maximum 32kHz, 10~12 [V]
Protective Function
Trip Over current trip, External signal trip, ARM short circuit current trip, Over heat trip, Input imaging trip, Ground trip, Motor over heat trip, I/O board link trip, No motor trip, Parameter writing trip, Emergency stop trip, Command loss trip, External memory error, CPU watchdog trip, Motor normal load trip, Over voltage trip, Temperature sensor trip, Drive over heat, Option trip, Output imaging trip, Drive overload trip, Fan trip, Pre-PID operation failure, External break trip, Low voltage trip during operation, Low voltage trip, Safety A(B) trip, Analog input error, Motor overload trip,
Alarm Command loss trip alarm, overload alarm, normal load alarm, drive overload alarm, fan operation alarm, resistance braking rate alarm, number of corrections on rotor tuning error
Momentary Power Loss HD below 15ms (ND below 8ms): Continuous operation (To be within rated input voltage, rated output) HD above 15ms (ND above 8ms): Automatic restart operation enable
Environment
Cooling Type Forced fan cooling structure Forced cooling type: 0.4~15 kW 200V/0.4~75 kW 400V (excluding some models)
Protection Degree IP20/UL Open (Default), UL Enclosed type 1 (Option), IP66/NEMA 4X (Option)
Ambient Temperature Ambient temperature under the condition of no ice or frost. HD: -10~50˚C(14~122˚F) / ND: -10~40˚C(14~104˚F) [However, recommended to use load below 80% when using at 50°C under light load]
Humidity Relative humidity below 95% RH (no dew formation)
Storage Temperature -20~65℃(-4~149°F)
Location No corrosive gas, flammable gas, oil mist and dust etc. indoors (Pollution degree 3 environment)
Altitude, Vibration Below 1,000m (From 1000 to 4000m, the rated input voltage and rated output current of the drive must be derated by 1% for every 100m.), below 9.8m/sec2 (1G)
Pressure 70~106kPa
Certificate/Compliance UL, CE
   2023 © Amerimation Inc.Volume 4.0.1